276°
Posted 20 hours ago

Siemens Multistix 8 SG Urine Reagent Test Strips - 100 Strips per Box: Accurate and Convenient Monitoring

£9.9£99Clearance
ZTS2023's avatar
Shared by
ZTS2023
Joined in 2023
82
63

About this deal

Applying a drop of control to the top of a test pad does not ensure optimum performance for each reagent. Do not drop control solution onto the ID band. To ensure optimum performance refer to “Proper dipping techniques for Siemens urinalysis test strips” above. Siemens is committed to continuous innovation in urinalysis and providing our customers with solutions for improved workflow and improved clinical information at the point of care.

Yes, if too much liquid is left on the ID band area. Dip It Right! Using the proper dipping technique greatly reduces the likelihood of these errors. A multicenter study was conducted to identify patients with potential UTIs. There were 1,887 urine specimens tested comparing the leukocyte and nitrite results of Multistix urinalysis strips to urine culture. A multicenter study was conducted to identify patients with potential UTIs. There were 1,887 urine specimens tested comparing the leukocyte and nitrite results of Multistix 10 SG urinalysis strips to urine culture. 1 The test strips can be used on Siemens’ CLINITEK Status ® and CLINITEK Advantus ® analyzers without impacting performance. Combining the results of leukocyte (WBC) and nitrite is a better predictor of the presence or absence of urinary tract infection, than any one test parameter alone. 2

Combining the results of leukocyte (WBC) and nitrite is a better predictor of the presence or absence of urinary tract infection, than any one test parameter alone. 3

Studies have shown that when urinalysis is performed with an instrument, sensitivity is increased and positives are correctly identified and reported. 4 Glucose — at 30 seconds look at the colour of the glucose square. If there is any glucose (or sugar) present it will change colour, possibly to a dark brown. Any amount of glucose in the urine needs further investigation by your GP – you may be diabetic. Nitrites — if nitrites are present then a pink colour shows. Nitrites are created when bacteria in the urine convert urea to nitrite – nitrites usually mean infection – see below Provides printed sample interference notes when common sample interferences are detected, providing healthcare professionals additional clinical information to aid in patient management.** Robertson AW, Duff P. The nitrite and leukocyte estarase tests for the evaluation of asymptomatic bacteriuria in obstetrics. Obstet. Gynnecol 1988;71:878-81.Leucocytes — if these are present in large amounts as for example in infection, then there is a colour change to purple. Studies have shown that when urinalysis is performed with an instrument, sensitivity is increased and positives are correctly identified and reported. 5 Protein — if protein is present then the colour changes to a bottle-green. Protein is a sign of disease of the renal tract — almost any kidney disease can present with protein in the urine.

Minimizes false-positive results with automatic notification if test strip has been degraded from humidity, preventing potentially erroneous patient results from being reported.* Can also be used with Siemens Clinitek Status and Clinitek Status+ Analysers for automatic analysis of results. No. The leukocyte pad is used to determine if the strip has been degraded from exposure to humidity. Only those Siemens strips with the leukocyte pad can detect humidity over-exposure.pH — this tells you how acid or alkali the urine is. It can be used as a guide to hyperventilation as it goes greeny blue (alkali) in people who hyperventilate. Siemens’ internal studies show that the ID band can be dipped without errors or strip misidentification issues if proper technique is used. Follow the Dip It Right! instructions listed above.

Enables user compliance with IVDD regulations by reporting results only from urinalysis strips that have been validated for use on the CLINITEK Status analyzers.Nitrites and leucocytes — these two tests together may suggest infection of the urinary tract. If one or other are positive then you must see your GP so that s/he can send a sample of urine off for microscopy and culture to see which bug is there and to which antibiotic it is sensitive. If you have symptoms such as fever, pain on peeing, urgency, constant desire to pee, feeling ill etc then an antibiotic should be started at once on a “best guess” basis (usually trimethoprim). If there are no symptoms then it is reasonable just to monitor the situation for a while. Urine testing with multistix is an extremely useful test to do on children who have a high temperature because urine infections are often overlooked as a possible cause of fever. Ketones — at 40 seconds look at the ketone square—if ketones are present then they may have changed to a dark purple. Ketones can be present in diabetes but the usual cause for them is hunger. If you’ve found ketones in your urine, go and have something to eat which includes some carbohydrate and test again after 30 minutes to 1 hour. If ketones are still present then you need to see your GP. One cause of ketones is a low carbohydrate diet used in some slimming regimes. Having ketones is not harmful (Eskimos are in a state of permanent ketosis). Eliminates the need to manually select strip type if using different urinalysis strips – saves time and reduces possible errors.

Asda Great Deal

Free UK shipping. 15 day free returns.
Community Updates
*So you can easily identify outgoing links on our site, we've marked them with an "*" symbol. Links on our site are monetised, but this never affects which deals get posted. Find more info in our FAQs and About Us page.
New Comment